Verified boiler fault code

Ferroli F05 Fault Code (i25 / i29)

Air-pressure switch did not close within 20 seconds of fan activation.

Safety disclaimer

Boiler repair help from Aza & Sons Services

Fault code summary

Manufacturer
Ferroli
Fault code
F05
Fault type
Fan, Flue, Electrical
Severity
temporary
Reset
Ferroli states that F faults reset automatically when the value returns to the normal range.
Applicable models
Ferroli i25, Ferroli i29

Quick answer

Air-pressure switch did not close within 20 seconds of fan activation.

What does this fault code mean?

Air-pressure switch did not close within 20 seconds of fan activation.

Common causes

  • Air-pressure switch contact open.
  • Pressure-switch wiring fault.
  • Wrong baffle.
  • Obstructed or incorrectly sized flue.
  • Dirty exchanger.
  • Faulty water circulation.

Symptoms

  • The display flashes F05 and the boiler temporarily shuts down.

What can the homeowner safely check?

  • Do not obstruct, dismantle or alter the flue; contact a qualified engineer.

Boiler reset information

Ferroli states that F faults reset automatically when the value returns to the normal range.

When should I call an engineer?

Contact a suitably qualified heating engineer when the fault persists, the boiler locks out, or the manufacturer instructions do not resolve it. For gas appliance work in the UK, use a Gas Safe registered engineer.

Engineer diagnosis

  • Check air-pressure switch, fan, wiring, baffle, flue and circulation.

Applicable boiler models

Related fault codes

Manufacturer documentation

i25 / i29 Instructions for use, installation and maintenance

Table 9: F05 — Air pressure switch fails to close contacts within 20 sec. of fan activation; table lists switch, wiring, baffle, flue, exchanger and circulation causes.

Last verified

2026-09-12

Frequently asked questions

What does Ferroli F05 mean?

Air-pressure switch did not close within 20 seconds of fan activation.

Can I reset a Ferroli F05 fault?

Ferroli states that F faults reset automatically when the value returns to the normal range.