Boiler model
Keston Keston Heat 2 55 Fault Codes
Verified fault-code information for the Heat 2 range.
Fault-code index
- 1 — Heat 2
Flow thermistor open circuit (blocking).
Read fault code - 10 — Heat 2
Water-pressure sensor defect.
Read fault code - 11 — Heat 2
Flow thermistor open circuit; lockout after 24 hours.
Read fault code - 12 — Heat 2
Flow thermistor short circuit; lockout after 24 hours.
Read fault code - 13 — Heat 2
Return thermistor open circuit; lockout after 24 hours.
Read fault code - 14 — Heat 2
Return thermistor short circuit; lockout after 24 hours.
Read fault code - 19 — Heat 2
Heat thermistor open circuit (blocking).
Read fault code - 2 — Heat 2
Flow thermistor short circuit (blocking).
Read fault code - 20 — Heat 2
Heat thermistor short circuit (blocking).
Read fault code - 3 — Heat 2
Return thermistor open circuit (blocking).
Read fault code - 30 — Heat 2
Blocking due to return overheat.
Read fault code - 31 — Heat 2
Blocking due to flue overheat.
Read fault code - 38 — Heat 2
Blocking delta-temperature supervision fault between flow and return.
Read fault code - 39 — Heat 2
Lockout due to flow overheat.
Read fault code - 40 — Heat 2
Lockout due to return overheat.
Read fault code - 42 — Heat 2
Blocking due to heat-exchanger overheat.
Read fault code - 50 — Heat 2
Blocking due to no central-heating water flow.
Read fault code - 51 — Heat 2
Low water pressure.
Read fault code - 52 — Heat 2
No flame signal at start; restart condition.
Read fault code - 53 — Heat 2
Flame loss during operation, with endless restarts activated.
Read fault code - 54 — Heat 2
Flame loss during operation, progressing to lockout after restart attempts are used.
Read fault code - 57 — Heat 2
False flame with a heat demand.
Read fault code - 59 — Heat 2
Fan-speed standstill check fault.
Read fault code - 60 — Heat 2
Fan speed not achieved, for example during pre-purge or post-purge.
Read fault code - 61 — Heat 2
Fan-speed error during pre-purge; repeated restarts can lead to lockout.
Read fault code - 62 — Heat 2
Fan-speed minimum/maximum supervision error during operation; restart condition.
Read fault code - 63 — Heat 2
Warning due to mains overvoltage.
Read fault code - 64 — Heat 2
Blocking due to mains undervoltage.
Read fault code - 65 — Heat 2
OpenTherm Plus communication error.
Read fault code - 66 — Heat 2
Too many remote resets.
Read fault code - 71 — Heat 2
PWM pump dry-run error (80% feedback).
Read fault code - 75 — Heat 2
Air-pressure-switch error.
Read fault code - 80 — Heat 2
Quartz-crystal error.
Read fault code - 99 — Heat 2
System lockout caused by an internal lockout error.
Read fault code