Verified boiler fault code

Vaillant F.22 Fault Code (ecoTEC plus/pro (manual models))

Dry fire.

Safety disclaimer

Boiler repair help from Aza & Sons Services

Fault code summary

Manufacturer
Vaillant
Fault code
F.22
Fault type
Low pressure, Pump, Circulation
Severity
high
Reset
Not specified
Applicable models
ecoTEC plus 612, ecoTEC plus 615, ecoTEC plus 618, ecoTEC plus 624, ecoTEC plus 630, ecoTEC plus 637, ecoTEC plus 824, ecoTEC plus 831, ecoTEC plus 837, ecoTEC pro 28

Quick answer

Dry fire.

What does this fault code mean?

Dry fire.

Common causes

  • Too little water in the appliance.
  • Water pressure sensor defective.
  • Cable to pump or water sensor defective.
  • Pump blocked or defective.
  • Pump output too low.

Symptoms

This information was not provided in the verified manufacturer source.

What can the homeowner safely check?

  • Check the pressure indication against the appliance instructions; do not remove the boiler casing.

Boiler reset information

Reset information was not provided in the verified manufacturer source. Do not repeatedly reset an unresolved fault.

When should I call an engineer?

Contact a suitably qualified heating engineer when the fault persists, the boiler locks out, or the manufacturer instructions do not resolve it. For gas appliance work in the UK, use a Gas Safe registered engineer.

Engineer diagnosis

  • Investigate system water quantity/pressure, pump operation, water-pressure sensing and wiring.

Applicable boiler models

Related fault codes

Manufacturer documentation

Instructions for installation and servicing ecoTEC

F.22 | Dry fire | Too little water in the appliance, water pressure sensor defective, cable to pump or water sensor defective, pump blocked or defective, pump output too low